check_brocade_fan |
Checks the status of a fan of a Brocade SAN Switch. |
check_brocade_overall |
Checks the overall status of a Brocade SAN Switch. |
check_brocade_port |
Checks the status of a FC interface of a Broacade SAN Switch. |
check_brocade_psu |
Checks the status of a power supply of a Brocade SAN Switch. |
check_brocade_temp |
Checks the status of a temperature sensor of a Brocade SAN Switch. |
check_cisco_cpuusage |
Checks the average cpu usage of a Cisco device. |
check_cisco_fan |
Checks the status of a fan of a Cisco device. |
check_cisco_if_load |
Checks the interface load of one of a Cisco device's network interfaces. |
check_cisco_mem |
Checks the usage of a memory pool of a Cisco device. |
check_cisco_pix_conns |
Checks the number of IP connections on a Cisco PIX Firewall. |
check_cisco_psu |
Checks the status of a power supply unit of a Cisco device. |
check_cisco_temp |
Checks the status of a temperature sensor of a Cisco device. |
check_cisco_voltage |
Checks the status of a voltage sensor of a Cisco device. |
check_cisco_vpn_conns |
Checks the number of connections (sessions) used on an a Cisco VPN Concentrator. |
check_cisco_vpn_cpuusage |
Checks the cpu usage of a Cisco VPN Concentrator. |
check_cisco_vpn_fan |
Checks whether a fan of Cisco VPN Concentrator has an alarm. |
check_cisco_vpn_temp |
Checks whether a temperature sensor of Cisco VPN Concentrator has an alarm. |
check_cisco_vpn_thru |
Checks the throughput utilization of a Cisco VPN Concentrator. |
check_cisco_vpn_voltage |
Checks whether a voltage sensor of a Cisco VPN Concentrator has an alarm. |
check_cpq_fan |
Checks the status of a fan of Compaq/HP server. |
check_cpq_fcaaccel |
Checks the status of a Compaq/HP External Array Accelerator. |
check_cpq_fcaeac |
Checks the status of a Compaq/HP External Array Controller. |
check_cpq_fcahctrl |
Checks the status of a Compaq/HPFibre Channel Host Controller. |
check_cpq_fcalogdrv |
Checks the status of a Compaq/HP External Array logical drive. |
check_cpq_fcaphydrv |
Checks the state of a physical drive in an external Compaq fibre channel array. |
check_cpq_fcaspare |
Checks the status of a Compaq/HP External Array spare drive. |
check_cpq_ida |
Checks the status of a Compaq/HP IDA Controller. |
check_cpq_phydrv |
Checks the state of a physical drive connected to a Compaq Intelligent Drive Array Controller. |
check_cpq_temp |
Checks the status of a temperature sensor of a Compaq server. |
check_cpq_thermal |
Checks the status of a Compaq/HP IDA Controller. |
check_if_by_snmp |
Checks the status of a network interface. |
check_netapp_battery |
Checks the NVRAM batteries of a NetApp Filer. |
check_netapp_du |
Checks the usage of a NetApp Filer volume. |
check_netapp_fans |
Checks the status of the fans of a NetApp Filer. |
check_netapp_ops |
Get the number of operations from a NetApp Filer. |
check_netapp_overall |
Checks the overall status of a NetApp Filer. |
check_netapp_psus |
Checks the status of the PSUs of a NetApp Filer. |
check_netapp_raiddrv |
Checks the state of a physical drive of a NetApp Filer. |
check_netapp_spare |
Checks the state of a spare drive of a NetApp Filer. |
check_netapp_temp |
Checks the temperature status of a NetApp Filer. |
check_netapp_vol |
Checks the status of a volume of a NetApp Filer. |
check_storage_by_snmp |
Checks the usage of some storage device (disk, ram, …). |
check_ucd_lms_fan |
Checks the value of a fan speed sensor which is monitored using lm_sensors. |
check_ucd_lms_temp |
Checks a temperature which is monitored using lm_sensors. |
check_ucd_lms_voltage |
Checks the voltage measured with a sensor which is monitored using lm_sensors. |
check_ucd_snmp_cpu |
Reports the cpu usage of a computer using the UCD-SNMP-MIB. |
check_ucd_snmp_load |
Checks the average system loads of a computer using the UCD-SNMP-MIB. |
check_ucd_snmp_mem |
Checks the memory usages of a computer using the UCD-SNMP-MIB. |
check_ups_alarms |
Checks if an UPS has any present alarms. |
check_ups_battery |
Checks the battery status of an UPS. |
check_ups_bypass |
Checks the status of an UPS bypass line. |
check_ups_input |
Checks the status of an UPS input line. |
check_ups_output |
Checks the status of an UPS output line. |
check_ups_outputs |
Checks the source of the output of an UPS. |
check_winf_cpuusage |
Reports the cpu usage of a Microsoft Windows computer using SNMP Informant. |
check_winf_mem |
Checks the memory usage of a Microsoft Windows computer using SNMP Informant. |