SNMP4Nagios
Home
Features
Requirements
Documentation
Downloads
Support
Legal
Contact

Features

  • Scanning for services.
  • Testing services (of course).
  • Logging of performance data, usually combined with testing (only some plugins).
  • Plotting performance data logs.
  • Supports SNMP Versions 1 and 2c.
  • Community strings can be passed using the command line or a file.

Plugin Synopsis

check_brocade_fan Checks the status of a fan of a Brocade SAN Switch.
check_brocade_overall Checks the overall status of a Brocade SAN Switch.
check_brocade_port Checks the status of a FC interface of a Broacade SAN Switch.
check_brocade_psu Checks the status of a power supply of a Brocade SAN Switch.
check_brocade_temp Checks the status of a temperature sensor of a Brocade SAN Switch.
check_cisco_cpuusage Checks the average cpu usage of a Cisco device.
check_cisco_fan Checks the status of a fan of a Cisco device.
check_cisco_if_load Checks the interface load of one of a Cisco device's network interfaces.
check_cisco_mem Checks the usage of a memory pool of a Cisco device.
check_cisco_pix_conns Checks the number of IP connections on a Cisco PIX Firewall.
check_cisco_psu Checks the status of a power supply unit of a Cisco device.
check_cisco_temp Checks the status of a temperature sensor of a Cisco device.
check_cisco_voltage Checks the status of a voltage sensor of a Cisco device.
check_cisco_vpn_conns Checks the number of connections (sessions) used on an a Cisco VPN Concentrator.
check_cisco_vpn_cpuusage Checks the cpu usage of a Cisco VPN Concentrator.
check_cisco_vpn_fan Checks whether a fan of Cisco VPN Concentrator has an alarm.
check_cisco_vpn_temp Checks whether a temperature sensor of Cisco VPN Concentrator has an alarm.
check_cisco_vpn_thru Checks the throughput utilization of a Cisco VPN Concentrator.
check_cisco_vpn_voltage Checks whether a voltage sensor of a Cisco VPN Concentrator has an alarm.
check_cpq_fan Checks the status of a fan of Compaq/HP server.
check_cpq_fcaaccel Checks the status of a Compaq/HP External Array Accelerator.
check_cpq_fcaeac Checks the status of a Compaq/HP External Array Controller.
check_cpq_fcahctrl Checks the status of a Compaq/HPFibre Channel Host Controller.
check_cpq_fcalogdrv Checks the status of a Compaq/HP External Array logical drive.
check_cpq_fcaphydrv Checks the state of a physical drive in an external Compaq fibre channel array.
check_cpq_fcaspare Checks the status of a Compaq/HP External Array spare drive.
check_cpq_ida Checks the status of a Compaq/HP IDA Controller.
check_cpq_phydrv Checks the state of a physical drive connected to a Compaq Intelligent Drive Array Controller.
check_cpq_temp Checks the status of a temperature sensor of a Compaq server.
check_cpq_thermal Checks the status of a Compaq/HP IDA Controller.
check_if_by_snmp Checks the status of a network interface.
check_netapp_battery Checks the NVRAM batteries of a NetApp Filer.
check_netapp_du Checks the usage of a NetApp Filer volume.
check_netapp_fans Checks the status of the fans of a NetApp Filer.
check_netapp_ops Get the number of operations from a NetApp Filer.
check_netapp_overall Checks the overall status of a NetApp Filer.
check_netapp_psus Checks the status of the PSUs of a NetApp Filer.
check_netapp_raiddrv Checks the state of a physical drive of a NetApp Filer.
check_netapp_spare Checks the state of a spare drive of a NetApp Filer.
check_netapp_temp Checks the temperature status of a NetApp Filer.
check_netapp_vol Checks the status of a volume of a NetApp Filer.
check_storage_by_snmp Checks the usage of some storage device (disk, ram, …).
check_ucd_lms_fan Checks the value of a fan speed sensor which is monitored using lm_sensors.
check_ucd_lms_temp Checks a temperature which is monitored using lm_sensors.
check_ucd_lms_voltage Checks the voltage measured with a sensor which is monitored using lm_sensors.
check_ucd_snmp_cpu Reports the cpu usage of a computer using the UCD-SNMP-MIB.
check_ucd_snmp_load Checks the average system loads of a computer using the UCD-SNMP-MIB.
check_ucd_snmp_mem Checks the memory usages of a computer using the UCD-SNMP-MIB.
check_ups_alarms Checks if an UPS has any present alarms.
check_ups_battery Checks the battery status of an UPS.
check_ups_bypass Checks the status of an UPS bypass line.
check_ups_input Checks the status of an UPS input line.
check_ups_output Checks the status of an UPS output line.
check_ups_outputs Checks the source of the output of an UPS.
check_winf_cpuusage Reports the cpu usage of a Microsoft Windows computer using SNMP Informant.
check_winf_mem Checks the memory usage of a Microsoft Windows computer using SNMP Informant.
SourceForge.net Logo    Copyright © 2006, 2007 Peter Gritsch